Nagoya Municipal Industrial Research Institute

Application of penetrant test to CFRP

Technical Classification:
[ Inspection & Analysis ]
Products:
Keyword:
[ Fluorescent penetrant test ] [ surface damage ]

Point of the Proposed Technology

・Application of the fluorescent penetrant test to CFRP with surface damage

Effect(s)

Microscopic damage which is difficult to visually observe can be observed.

New Technology

Technology Deployment and Cooperation

Development Stage Prototyping / experimental Stage (to be completed in 0/0; progress: 0%)
Intellectual Property Right None
Joint Researchers (their role)
Example of Application ・Observation of CFRP surface crack
Technical Problems ・In order to check for damage from the surface to the inside, inspection in combination with ultrasonic test, X-ray penetrant test or the like is required.
Collaborator needed to Improve ・Companies and research institutions which use generation and proceeding behavior of microscopic damage for design or the like.
・Companies and research institutions which conduct the non-destructive inspection of CFRP
Technical WEB pagehttps://www.nmiri.city.nagoya.jp/index.html

Inquiries

Personnel / DepartmentProduct Evaluation Laboratory, System Technology Department / Satoshi FUKAYA
Address 3-4-41, Rokuban, Atsuta-ku Nagoya-shi, Aichi, 456-0058, Japan
Contact TEL: +81-52-661-3161
FAX: +81-52-654-6788

Outline of Company and Organization

Location 3-4-41, Rokuban, Atsuta-ku Nagoya-shi, Aichi, 456-0058, Japan
Contact TEL: +81-52-661-3161 FAX: +81-52-654-6788
Capital / No. of Employees0 yen・93 employees
Product Line
Major Customers
Overseas Base(s)
Certification
Company/Organization WEB pagehttp://www.nmiri.city.nagoya.jp

Update date: 2020/1/23